Troubleshooting 169
Synapse Installation Guide
.Some devices did not update
after using .
Did not allow enough time for
software to update due to a
slow Internet connection.
Wait 30 minutes, then check whether additional devices
have been updated. If devices are still being updated, then
the Internet connection is slow and you must wait for all
the devices to complete the update process.
If the update has failed (you see a failure message), retry
. Allow sufficient time for the upgrade
process to complete. You may prefer to schedule a system
update to take place overnight.
Update individual devices manually either through the
front panel or through the WebUI for that particular
device.
Power cycle each device that did not get upgraded.
Unplug the power cord and plug it back in. As each device
reboots, it automatically updates (if it detects updated
software in the system).
The Outgoing Caller ID
option does not appear on
the Extension Basic
Settings page of the
administrator WebUI.
A DID number has not been
assigned.
Assign a DID number to the extension.
a. On the WebUI, click Extension Settings, then
Basic Settings.
b. Select a DID number from the Select DID drop-down
list.
Symptom Probable Cause Corrective Action Administrator WebUI
If you are using the WebUI to upgrade the device,
ensure that you log in using that device’s IP address.