Troubleshooting 192
Synapse Installation Guide
Multi-Zone OHP Connected to an FXS Port
Symptom Probable Cause Corrective Action ATA Multi-Zone OHP to an FXS Port
For OHP equipment connected to an FXS port, this Troubleshooting refers to the ATA front-panel FXS LED for the FXS port you
are using for the OHP equipment. When the equipment is properly installed, and everything is configured correctly, this is the
behavior of these LEDs:
OFF: There is no paging activity.
Flashing GREEN: A user has initiated a page.
Solid GREEN: A device other than an OHP (such as a fax machine) is connected to the FXS port and has gone off hook.
We also use these LEDs to help diagnose problems.
With multi-zone paging,
paging all extensions does
not broadcast over my OHP
equipment.
Multi-zone OHP can not be
paged at the same time as
Desksets.
To page the OHP, the user must select Overhead Paging
from the Paging Zones selection screen on the Deskset.
Selecting any other zone will not page the OHP system,
even if the Paging Zones did include Overhead Paging
prior to changing the Paging System Type to
multi-zone.
Multi-zone OHP is not
working.
Inconsistent configuration.
Verify the Multi-Zone WebUI configuration:
a. Log in to the WebUI as administrator, click
System Settings –> Overhead Paging.
b. Verify that Paging is set to Enable.
c. Verify that the Paging System Type is set to
Multi Zone.
d. Verify that Select Paging Port is set to an FXS port
and that your OHP system is physically plugged into
that FXS port.
e. Click .