System Configuration 110
Synapse Installation Guide
T1 Settings
You can modify the settings of your T1 connection. AT&T expects that most installations will use the default settings. Changing
T1 settings resets the T1 Gateway and interrupts telephone service. To avoid disrupting service, AT&T recommends changing T1
settings outside of business hours.
These settings apply to Call Appearance mode only.
To configure the T1 settings:
Figure 121. T1 Settings
1. In the Navigation Menu at left, click System
Settings, then T1 Settings. The page shown in
Figure 121 appears.
The system assumes that your T1 circuit uses
B8ZS
(Bipolar with 8 Zeros Substitution)
Encoding
.
The system assumes that your T1 circuit uses ESF
(Extended Super Frame), used in conjunction with
B8ZS, for signaling and to control line Framing.
2. Select the Signaling protocol from the drop-down
list. Signaling information is sent with the data to
convey certain connection parameters. The default
is Primary Rate Interface (PRI NI-2), which is the
modern standard for carrying voice transmissions.
The other choices are Nortel Digital Multiplex
Switch 100 (DMS-100), and Class 5 Electronic
Switching System (5ESS). With these two protocols,
only the caller ID number, not the caller ID name,
is provided to the Desksets.