MERLIN LEGEND Communications System Release 5.0
System Planning
555-650-112
Issue 1
June 1997
Unit Load Calculation
Page F-4
F
6. Calculate the actual carrier unit load.
■
If the total actual unit load is less than or equal to 54 (391A1 or 391A2
power supplies) or less than or equal to 75 (391A3 power supply), no fur-
ther calculation is required.
■
If the total actual unit load is more than 54 (391A1 or 391A2 power sup-
plies) or more than 75 (391A3 power supply), continue to Step 7.
Module Qty x Unit
Load
= Total
008 12.0
008 MLX 13.25
008 OPT 8.0
012 8.4
016 12.8
100D 0.0
400 0.0
400 EM 8.0
400 GS/LS/TTR 0.0
408 12.0
408 GS/LS 12.0
408
GS/LS-MLX
13.5
800 0.0
800 GS/LS 0.0
800 DID 8.0
800 GS/LS-ID 8.0
MERLIN LEGEND Mail 0.0
Total Estimated Unit Load
■
If total is less than 54 (for the 391A1 or 391A2 power supplies) or 75
(for the 391A3 power supply), no further calculation is required.
■
If total is 54 (391A1 or 391A2 power supplies) or 75 (391A3 power sup-
ply) or more, continue to Step 6.