MERLIN LEGEND Communications System Release 5.0
System Planning
555-650-112
Issue 1
June 1997
T1/PRI Planner
Page D-4
D
The communications system in Figure D-1 is configured as follows:
Module 1 in slot 04 is connected to an ACCULINK 3150 CSU that is approx-
imately 100 cable feet from the control unit. (The DS1 facility is connected
to the PRI network.)
Module 2 in slot 05 is connected to an ACCULINK 3150 CSU that is approx-
imately 160 cable feet from the control unit. (The far end is another commu-
nications system.)
The primary clock synchronization source is the PRI network connected to
Module 1. Its path is shown by a line and the letter
P.
The secondary clock synchronization path, shown by a line and the letter S,
is the system internal clock.