System Programming Reference
System Programming changes settings for the system as a whole, or for individual lines or extensions. You can also use System
Programming to set up dialing restrictions, define groups, and set up optional equipment.
Place the Programming Overlay on the dial pad of the system display phone at extension 10 or 11
TO START SYSTEM PROGRAMMING TO USE A SPECIFIC PROCEDURE
TO CYCLE THROUGH AVAILABLE
PRESS [
Feature
] [
0
] [
0
]
DIAL [ # ] and the three-digit procedure code
SETTINGS
PRESS [
System Program
]
Example: [
#
] [
1
] [
0
] [
1
] for System Date
PRESS [
Next Data
] or [
Prev Data
]
PRESS [
System Program
]
TO CYCLE THROUGH SYSTEM PROGRAMMING
TO RETURN TO FACTORY SETTING
PROCEDURES
PRESS [
Remove
]
TO END SYSTEM PROGRAMMING
PRESS [
Next Procedure
] or [
Prev Procedure
]
PRESS [
Feature
] [
0
] [
0
]
NOTE: Procedures #399, #609, and #728—shown
below in dashed boxes—are skipped when cycling
SYSTEM
SYSTEM DATE
Sets the month, day, and year to appear on
system display phones (MLS-34D and
MLS-12D). Include leading zeroes for
single-digit months or days (for example,
January 3, 1992, is entered as 010392).
DIAL #101
DIAL the date in MMDDYY form
DIAL #108
SYSTEM DAY
Sets the day of the week to appear on
system display phones (MLS-34D and
MLS-12D).
DIAL #102
DIAL
1 = Sunday
2 = Monday
3 = Tuesday
4 = Wednesday
5 = Thursday
6 = Friday
7 = Saturday
SYSTEM TIME
Sets the time to appear on system display
phones (MLS-34D and MLS-12D). Enter
four digits in 24-hour military notation, from
0000 for 12 midnight to 2359 for 11:59 p.m.
(for example, 8:15 a.m. = 0815). System
displays times as a.m. or p.m.
DlAL #103
DIAL the time in HHMM form
TRANSFER RETURN RINGS
ROTARY DIALING TIMEOUT
For all system extensions, defines the
Change the factory setting only if you
number of times transferred calls ring
have trouble calling out on rotary lines
before returning to the extension that
with standard touch-tone phones. (For
transferred the call (or to a programmed
Transfer Return Extension, #306).
example, if users dial slowly and calls are
not completed or are connected to wrong
NOTE: For fax, answering machine, or
numbers, lengthen the timeout.) Use only
auto attendant extensions, set this
if the Dial Mode (#201) for at least one line
is set to “rotary.”
number to be greater than the ring delay
for the device, to prevent calls from being
returned before the device answers.
DIAL
1 = 4 seconds
DIAL #105
2 = 8 seconds
DIAL one digit for the number of rings
3 = 12 seconds
before the call returns (0 to 9)
= 4 rings
0 rings = no return
OUTSIDE CONFERENCE
Determines whether users can include
more than one outside party in a confer-
ence call (affects all system users).
RECALL TIMER DURATION
DIAL #109
The Recall feature sends a timed signal
(switchhook flash) to your local phone
DIAL
1 = Allowed
company. This setting changes the length
2 = Disallowed
of the signal in 25-millisecond (msec)
increments. (For example, 01 = 25 msec,
SYSTEM RESET PROGRAMMING
80 = 2000 msec.)
SAVED
if:
Factory setting is correct for most PBX
systems. Change the factory setting only
IMPORTANT: Using this procedure
disconnects any active calls but retains
using Recall drops calls (shorten the
system settings. Use it only if the system
time).
fails to function correctly after a power
failure or down period.
using Recall has no effect—i.e., no
dial tone (lengthen the time).
DIAL #728
DIAL #107
NUMBER OF LINES
Use only when first setting up the system,
to assign the same number of outside
lines to all extensions. (For example,
entering 06 means that all extensions are
assigned lines 1–6.)
DIAL #104
DIAL two digits for the number of outside
lines in the system (01 to 24)
2 per 206 module plus 4 per 400
module
IMPORTANT: Do not use this
procedure if you add lines to the system
after initial setup because it changes
Line Access Restriction (#302),
Automatic Line Selection, Line Ringing,
and Hold Disconnect Time (#203) for
existing lines lines back to factory
settings. To change line assignments
without affecting other settings, use Line
Assignment (#301).
DIAL two digits to set the length of a
switchook flash (01 to 80)
= 18 (450 msec)
= Factory Setting